Abstract Kyriakis N, Michopoulos A, Pattas K:
"Ground Heat Exchanger of Pylaia. Energy Evaluation after the First Year of Operation",
Tech. Chron. Science Journal, TCG, IV 22 (1-2) : 41-48 (Dec 2002)


Keywords    
Abstract   The distribution of energy demand over the year for air-conditioning (heating and cooling) of the New City Hall of Pylaia Thessaloniki is presented. A system of water-to-water heat pumps was selected to cover this demand, supported by a ground heat exchanger of 3500 m in total underground piping. The operation of the system is being monitored and the most critical data are recorded at a time interval of 10 min. The energy consumption of the building during the first year of operation of the system is presented and compared to that of conventional heating and cooling systems (diesel fuel boiler, air-to-water and air-to-air heat pumps). The comparison shows a significant reduction of the air-conditioning energy demand, as a result of the utilization of the ground heat exchanger.
Full text   Full Text in PDF (817 KB)
Source link   http://portal.tee.gr/portal/page?_pageid=48,414019&_dad=portal&_schema=PORTAL92
Included Refrences   6 References (List...)
Cited by other Articles   0 Citations (List...)

Authors:

 3 records found.
Name Affiliation Home page e-mail Total pubs 
Kyriakis NProcess Equipment Design Laboratory, Department of Mechanical Engineering AUTH P.C. 541 24, Thessaloniki, Greece nkyr@auth.gr10
Michopoulos AProcess Equipment Design Laboratory Department of Mechanical Engineering, Aristotle University Thessaloniki, 54124 Thessaloniki, Greece  3
Pattas KProcess Equipment Design Laboratory, Department of Mechanical Engineering, Aristotle University Thessaloniki, 54124 Thessaloniki, Greece  3

Article is cited by:

 No records found.

References included in article:

 6 records found.
Order of appearence Full citation SRCosmos Link 
1Climaveneta, Technical Sheet of Heat Pump type HRAN 0091B. 
2Βραχόπουλος Μ, Παπαγεωργάκης Ι,
(1998), «Εκμεταλλεύσιμη Ηλιογενής και Γηγενής Θερμότητα στο Αβαθές Υπέδαφος της Αττικής», Τεχν. Χρον. Επιστ. Έκδ. ΤΕΕ, IV, τεύχ. 1, σελ. 55 - 66.
 
3Popiel C, Wojtkowiak J, Biernacka B,
(2001), «Measurements of Temperature Distribution in Ground», Experimental Thermal and Fluid Science, 25, pp. 301 – 309, Elsevier.
 
4Paepe M,
(2001), «Market Opportunities for Advanced Ventilation Technology», 22nd Annual AIVC Conference, UK 11-14/09/2001.
 
5Pahud D, Matthey B,
(2001), «Comparison of the Thermal Performance of Double U-pipe Borehole Heat Exchangers Measured in-situ», Energy and Buildings 33 (2001) pp. 503 – 507, Elsevier.
 
6Παπακώστας Κ,
(2001), «Συμβολή στην Εκτίμηση της Κατανάλωσης Ενέργειας σε Συστήματα Θέρμανσης και Κλιματισμού στην Ελλάδα με τη Χρήση Μεθόδων Απλής και Πολλαπλής Μέτρησης», Διδακτορική Διατριβή, Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης. Τμήμα Μηχανολόγων Μηχανικών.